USGS 12323670 Mill Creek nr Anaconda, MT

Deer Lodge County, Montana
Hydrologic Unit Code 17010201
Latitude  46°04'58.70", Longitude 112°55'01.88" NAD83
Drainage area 39.5  square miles
Gage datum 5,470 feet above NAVD88
Period of record
Begin Date End Date Samples
2004-10-26 2022-07-12 218
Select one or more parameter codes from the list.
When you are finished selecting parameter codes, set your output format using the available options below.
Parameter
Code
Count Begin
Date
End
Date
Parameter Code Complete Name
00004 52 2004-10-26 2022-07-12 Stream width, feet
00010 218 2004-10-26 2022-07-12 Temperature, water, degrees Celsius
00020 200 2004-10-26 2022-07-12 Temperature, air, degrees Celsius
00028 27 2004-10-26 2022-07-12 Agency analyzing sample, code
00041 9 2004-10-26 2022-07-12 Weather, World Meteorological Organization (WMO) code
00060 1 2004-10-26 2022-07-12 Discharge, cubic feet per second
00061 191 2004-10-26 2022-07-12 Discharge, instantaneous, cubic feet per second
00063 53 2004-10-26 2022-07-12 Number of sampling points, count
00065 204 2004-10-26 2022-07-12 Gage height, feet
00095 210 2004-10-26 2022-07-12 Specific conductance, water, unfiltered, microsiemens per centimeter at 25 degrees Celsius
00191 143 2004-10-26 2022-07-12 Hydrogen ion, water, unfiltered, calculated, milligrams per liter
00400 143 2004-10-26 2022-07-12 pH, water, unfiltered, field, standard units
00403 138 2004-10-26 2022-07-12 pH, water, unfiltered, laboratory, standard units
00405 65 2004-10-26 2022-07-12 Carbon dioxide, water, unfiltered, milligrams per liter
00681 68 2004-10-26 2022-07-12 Organic carbon, water, filtered, milligrams per liter
00900 138 2004-10-26 2022-07-12 Hardness, water, milligrams per liter as calcium carbonate
00905 14 2004-10-26 2022-07-12 Noncarbonate hardness, water, filtered, lab, milligrams per liter as calcium carbonate
00915 138 2004-10-26 2022-07-12 Calcium, water, filtered, milligrams per liter
00925 138 2004-10-26 2022-07-12 Magnesium, water, filtered, milligrams per liter
00930 65 2004-10-26 2022-07-12 Sodium, water, filtered, milligrams per liter
00931 65 2004-10-26 2022-07-12 Sodium adsorption ratio (SAR), water, number
00932 65 2004-10-26 2022-07-12 Sodium fraction of cations, water, percent in equivalents of major cations
00935 65 2004-10-26 2022-07-12 Potassium, water, filtered, milligrams per liter
00940 65 2004-10-26 2022-07-12 Chloride, water, filtered, milligrams per liter
00945 65 2004-10-26 2022-07-12 Sulfate, water, filtered, milligrams per liter
00950 65 2004-10-26 2022-07-12 Fluoride, water, filtered, milligrams per liter
00955 65 2004-10-26 2022-07-12 Silica, water, filtered, milligrams per liter as SiO2
01000 138 2004-10-26 2022-07-12 Arsenic, water, filtered, micrograms per liter
01002 138 2004-10-26 2022-07-12 Arsenic, water, unfiltered, micrograms per liter
01025 137 2004-10-26 2022-07-12 Cadmium, water, filtered, micrograms per liter
01027 138 2004-10-26 2022-07-12 Cadmium, water, unfiltered, micrograms per liter
01040 137 2004-10-26 2022-07-12 Copper, water, filtered, micrograms per liter
01042 137 2004-10-26 2022-07-12 Copper, water, unfiltered, recoverable, micrograms per liter
01045 138 2004-10-26 2022-07-12 Iron, water, unfiltered, recoverable, micrograms per liter
01046 138 2004-10-26 2022-07-12 Iron, water, filtered, micrograms per liter
01049 138 2004-10-26 2022-07-12 Lead, water, filtered, micrograms per liter
01051 138 2004-10-26 2022-07-12 Lead, water, unfiltered, recoverable, micrograms per liter
01055 138 2004-10-26 2022-07-12 Manganese, water, unfiltered, recoverable, micrograms per liter
01056 138 2004-10-26 2022-07-12 Manganese, water, filtered, micrograms per liter
01090 138 2004-10-26 2022-07-12 Zinc, water, filtered, micrograms per liter
01092 138 2004-10-26 2022-07-12 Zinc, water, unfiltered, recoverable, micrograms per liter
29801 65 2004-10-26 2022-07-12 Alkalinity, water, filtered, fixed endpoint (pH 4.5) titration, laboratory, milligrams per liter as calcium carbonate
30207 204 2004-10-26 2022-07-12 Gage height, above datum, meters
30208 1 2004-10-26 2022-07-12 Discharge, cubic meters per second
30209 191 2004-10-26 2022-07-12 Discharge, instantaneous, cubic meters per second
50014 9 2004-10-26 2022-07-12 Transit rate, sampler, minimum, feet per second
50015 41 2004-10-26 2022-07-12 Transit rate, sampler, feet per second
50016 9 2004-10-26 2022-07-12 Transit rate, sampler, maximum, feet per second
50280 54 2004-10-26 2022-07-12 Site visit purpose, code
63676 135 2004-10-26 2022-07-12 Turbidity, water, unfiltered, broad band light source (400-680 nm), detectors at multiple angles including 90 +-30 degrees, ratiometric correction, NTRU
70301 65 2004-10-26 2022-07-12 Dissolved solids, water, filtered, sum of constituents, milligrams per liter
70302 56 2004-10-26 2022-07-12 Dissolved solids, water, short tons per day
70303 65 2004-10-26 2022-07-12 Dissolved solids, water, filtered, short tons per acre-foot
70331 140 2004-10-26 2022-07-12 Suspended sediment, sieve diameter, percent smaller than 0.0625 millimeters
71999 13 2004-10-26 2022-07-12 Sample purpose, code
72104 2 2004-10-26 2022-07-12 Sample location, distance downstream, feet
72105 4 2004-10-26 2022-07-12 Sample location, distance upstream, feet
72219 53 2004-10-26 2022-07-12 Sampler nozzle material, code
72220 52 2004-10-26 2022-07-12 Sampler nozzle diameter, code
80154 140 2004-10-26 2022-07-12 Suspended sediment concentration, milligrams per liter
80155 128 2004-10-26 2022-07-12 Suspended sediment discharge, short tons per day
81904 31 2004-10-26 2022-07-12 Velocity at point in stream, feet per second
82398 143 2004-10-26 2022-07-12 Sampling method, code
84164 143 2004-10-26 2022-07-12 Sampler type, code
84171 53 2004-10-26 2022-07-12 Sample splitter type, field, code
84182 53 2004-10-26 2022-07-12 Bottle or bag sampler material (construction), code
90095 137 2004-10-26 2022-07-12 Specific conductance, water, unfiltered, laboratory, microsiemens per centimeter at 25 degrees Celsius
91157 28 2004-10-26 2022-07-12 Suspended sediment, sediment mass recovered from whole water sample, dry weight, grams
91165 28 2004-10-26 2022-07-12 Suspended sediment, between 0.063 and 4 mm sieve diameter, sediment mass analyzed for particle size fractions, dry weight, grams
99105 4 2004-10-26 2022-07-12 Type of replicate, code
99111 20 2004-10-26 2022-07-12 Type of quality assurance data associated with sample, code
99156 62 2004-10-26 2022-07-12 Sulfuric acid NWIS lot number, 4.5 N (1:7), 1 mL, National Field Supply Service (NFSS) stock number Q438FLD
99159 62 2004-10-26 2022-07-12 Nitric acid NWIS lot number, 7.5-7.7 N, 2 mL, National Field Supply Service (NFSS) stock number Q436FLD
99161 50 2004-10-26 2022-07-12 Conductance standard NWIS lot number, 100 uS/cm KCl, National Field Supply Service (NFSS) stock number Q43FLD
99163 42 2004-10-26 2022-07-12 Conductance standard NWIS lot number, 500 uS/cm KCl, National Field Supply Service (NFSS) stock number Q45FLD
99164 27 2004-10-26 2022-07-12 Conductance standard NWIS lot number, 750 uS/cm KCl, National Field Supply Service (NFSS) stock number Q46FLD
99165 10 2004-10-26 2022-07-12 Conductance standard NWIS lot number, 1000 uS/cm KCl, National Field Supply Service (NFSS) stock number Q47FLD
99171 52 2004-10-26 2022-07-12 pH 10 Buffer solution, NWIS lot number, National Field Supply Service (NFSS) stock numbers Q122FLD, Q123FLD
99172 11 2004-10-26 2022-07-12 pH 4 Buffer solution, NWIS lot number, National Field Supply Service (NFSS) stock numbers Q124FLD, Q125FLD
99173 53 2004-10-26 2022-07-12 pH 7 Buffer solution, NWIS lot number, National Field Supply Service (NFSS) stock numbers Q126FLD, Q127FLD
99177 6 2004-10-26 2022-07-12 Conductance standard NWIS lot number, 1800 uS/cm KCl, National Field Supply Service (NFSS) stock number Q383FLD
99200 1 2004-10-26 2022-07-12 Lot number, first, inorganic-grade water, number
99206 61 2004-10-26 2022-07-12 NWIS lot number, capsule filter, 0.45 micron
99870 15 2004-10-26 2022-07-12 Julian date, in-bottle digestion, ddd
 
Choose Output Format

Retrieve Water-Quality Samples for Selected Sites
Choose one of the following options for displaying data for the sites meeting the criteria above
?
Parameter Group Period of Record table
?
?
*
?
Retrieve data from: to: (YYYY-MM-DD -- Blank = all data)
?
Retrieve sample time and time zone as stored   in UTC
?
Retrieve samples for specified parameter values: (Parameter Code) (Numeric Value)
?
Samples and parameters to include:
   Samples that include only above parameter selection criteria (Count: 0)
   Samples that include above selection criteria and all associated parameters
   
    <--Find parameter codes
   Samples that include above selection criteria plus one or more of these parameters in a file
    Enter the full pathname of a file containing parameter codes. (Limit: 200 codes)
    

?
Table of data
?
Tab-separated data *

 * Save compressed files with a .gz file extension.