Page Loading - Please Wait...
Water-Year Summary for Site 07241550
10/01/2023- 09/30/2024 records good.
Quality of data for other periods can be obtained by contacting the Oklahoma-Texas Water Science Center.
Flow regulated by Canton Lake (station 07238500) and by Lake Overholser (station 07240500) where diversions are made into Lake Hefner Canal (station 07240000). Low flow sustained in part by sewage effluent.
WATER TEMPERATURE: October 1968 to current year. Data available prior to 10/01/2007 has been graded as unusable.
SPECIFIC CONDUCTANCE: October 1968 to current year. Data available prior to 10/01/2007 has been graded as unusable.
pH: October 1988 to current year. Data available prior to 10/01/2007 has been graded as unusable.
DISSOLVED OXYGEN: October 1988 to current year. Data available prior to 10/01/2007 has been graded as unusable.
Accuracy rating of the record for the 2024 Water Year:
WATER TEMPERATURE: Good; Some large portions of data loss occurred mostly due to equipment malfunctions and monitor maintenance. The sensor underwent NIST checks on a quarterly basis, but no EWI, depth-integrated cross-section surveys were completed within this water year.
SPECIFIC CONDUCTIVITY: Good; Fouling and calibration drift corrections were applied throughout the water year. Some data loss occurred due to data deletions, equipment malfunctions, and monitor maintenance. Additionally, no cross-section surveys were completed throughout this water year.
PH: Fair; Fouling and calibration drift corrections were applied throughout the water year. Some data loss occurred due to data deletions, equipment malfunctions, and monitor maintenance. Additionally, no cross-section surveys were completed throughout this water year.
DISSOLVED OXYGEN: Poor; Fouling and calibration drift corrections were required throughout the water year, some of fairly large magnitude which exceeded the maximum allowable limit of corrections. Some data loss occurred due to data deletions, equipment malfunctions, and monitor maintenance. Additionally, no cross-section surveys were completed throughout this water year.
Quality of data for other periods can be obtained by contacting the Oklahoma-Texas Water Science Center.
WATER TEMPERATURE:
Maximum: 36.5°C on 08/01/2012*
Minimum: -1.0°C on 01/01/2018*
SPECIFIC CONDUCTANCE:
Maximum: 2170 µS/cm on 07/17/2018*
Minimum: 129 µS/cm on 08/17/2017
pH:
Maximum: 9.8 units on 06/06/2018*
Minimum: 6.7 units on 02/28/2015*
DISSOLVED OXYGEN:
Maximum: 23.0 mg/L on 06/15/2016
Minimum: 0.1 mg/L on 04/08/2009*