USGS 01362497 LITTLE BEAVER KILL AT BEECHFORD NEAR MT TREMPER NY

PROVISIONAL DATA SUBJECT TO REVISION

Click to hidestation-specific text

 

> Site Information
LOCATION.--Lat 42°01'10", long 74°15'59" referenced to North American Datum of 1983, Ulster County, NY, Hydrologic Unit 02020006, on right bank 950 ft upstream from State Highway 28 at Beechford, 0.3 mi above mouth, and 1.8 mi southeast of Mount Tremper.
DRAINAGE AREA.--16.5 mi².
PERIOD OF RECORD.--October 1997 to current year.
REVISIONS HISTORY.--WDR NY-99-1: 1998. WDR NY-01-1: 1998-2000.
GAGE.--Water-stage recorder and crest-stage gage. Datum of gage is 659.04 ft above NGVD of 1929 and 658.36 ft above NAVD of 1988.
REMARKS.--Water Years 2014-23: Records fair except those for estimated daily discharges, which are poor.
EXTREMES FOR PERIOD OF RECORD.--Maximum discharge, 2,820 ft³/s, June 26, 2006, gage height, 8.71 ft; minimum discharge, 0.11 ft³/s, Sept. 8, 9, 2002; minimum gage height, 1.41 ft, Aug. 12, 13, 1999.
PERIOD OF RECORD1.--November 2010 to current year.
PERIOD OF DAILY RECORD1.--TURBIDITY: DTS12 - November 2010 to December 2014, September 2016 to current year. Analite - August 2022 to current year.
INSTRUMENTATION1.--An optical turbidity sensor provides readings at 15-minute intervals since November 2010.
COOPERATION1.--In cooperation with the New York City Department of Environmental Protection.
EXTREMES FOR PERIOD OF DAILY RECORD1.--TURBIDITY: DTS12 - Maximum, 859 FNU, Aug. 28, 2011; minimum, <0.2 FNU, on many days. Analite - Maximum, 880 FNU, Aug. 30, 2023; minimum, <0.2FNU, on several days. [<, actual value is known to be less than the value shown]
1 Water-Quality Records
> Rating Information
This station managed by the NY Water Science Center Troy.

Available Parameters Available Period
  
1997-10-01  2024-11-26
2007-10-01  2024-11-26
2010-11-16  2024-10-29
2022-08-17  2024-11-26
2021-11-27  2022-09-30
2021-11-27  2022-09-30







 (7)
 

  -- or --

 


 

Summary of all available data for this site
Instantaneous-data availability statement


Turbidity, water, unfiltered, monochrome near infra-red LED light, 780-900 nm, detection angle 90 +-2.5 degrees, formazin nephelometric units (FNU), Analite, [Observator, Analite NEP 5000 S]

Most recent instantaneous value: 107 11-26-2024   16:45 EST
Graph of  Turbidity, water, unfiltered, monochrome near infra-red LED light, 780-900 nm, detection angle 90 +-2.5 degrees, formazin nephelometric units (FNU), [Observator, Analite NEP 5000 S]

Add up to 2 more sites and replot for "Turbidity, water, unfiltered, monochrome near infra-red LED light, 780-900 nm, detection angle 90 +-2.5 degrees, formazin nephelometric units (FNU), Analite, [Observator, Analite NEP 5000 S]"

?
 


Create presentation-quality / stand-alone graph.   Subscribe to WaterAlert      

See this graph on the Monitoring Location Pages



Turbidity, water, unfiltered, monochrome near infra-red LED light, 780-900 nm, detection angle 90 +-2.5 degrees, formazin nephelometric units (FNU), [Forest Technology Systems DTS-]
 
-- Data temporarily unavailable for the time period specified --